MODEL
FMDB
Electro-proportional 3-way flow control valve, meter in
SERIES 1 / CAPACITY: 23 L/min. / CAVITY: T-11A
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at
port 1 and port 2 connected to tank at port 3. Energizing the coil generates a closing force on the spool, creating a
metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates
in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow
control. Flow in the 2 to 3 direction is not proportional.
TECHNICAL DATA
Maximum Valve Leakage at 110 SUS (24 cSt) 30 cc/min.@70 bar
Manual Override Force Requirement 33 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-411-007
Seal kit - Cartridge Viton: 990-411-006
(X)CONTROL
X No Manual Override
D Twist/Lock (Dual) Manual Override
E Twist (Extended) Manual Override
L Twist/Lock (Detent) Manual Override
M Manual Override
T Twist (Momentary) Manual Override
(C)FLOW RATE
C .1 - 6 gpm (0,4 - 23 L/min.)
A .1 - 1.6 gpm (0,4 - 6.1 L/min.)
B .1 - 4 gpm (0,4 - 15 L/min.)
(N)SEAL MATERIAL
N Buna-N
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
FMDB
TECHNICAL FEATURES
The transition between positions is closed.
Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic
element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
All ports will accept 5000 psi (350 bar).
Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control
assemblies have a mechanical life expectancy of approximately 7,000 cycles.
The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
NOTES
Model Code Example: FMDBXCNCONFIGURATION OPTIONS